ICS-Schneider Messtechnik GmbH
  • Deutsch
  • English
  • Products
  • Company
    • About Us
    • Jobs & Carrers
    • Calibration
  • News
    • News
    • Sale actions
  • Downloads
  • Contact

Products

  • Manometer / Gauges / Accessories
  • Thermometer / Temperature sensors
  • Pressure and Temperature switches
  • Pressure sensors / Transmitter / diff. Pressure sensors / Level sensors
  • Flowsensors / Waysensors / Powersensors / Waagen
  • Humiditysensors / Velocitysensors
  • Calibrators, Test kits
  • Calibration pumps
  • Pressure controller
  • Pressure meters
  • Temperature meters / Thermography
  • Gas meters and Gas sensors
  • Dataloggers and Measuring systems
  • Minimess
  • Analog meters/ Digital meters / Current Voltage transformers / Transducers / Buffer
  • Network equipment
  • Dynisco products
  • Energy meters / VDE check equipment
    • Voltage testers
    • Clamp meters / Flexible transducers
    • Analog / Digital multimeters
    • Resistance meters / Microohm meters
    • Power and energy meters / Network meters
    • VDE Hardware checker / VDE 0100 / VDE 0701-0702 / VDE 0113
    • Isolation meters
    • Grounding test measurer
    • Welding units - Tester
    • Tester energy supply
    • Battery testers
    • Oscilloscope
    • Laser rangefinder / Cable altimeters
    • Illumination meters / Thickness meters / Wall thickness / Rotation speed meters / Soundlevel / Field intensity
    • Photovoltaics equipment
  • Home
  • Products
  • Energy meters
  • Battery testers

Battery testers

TMC 2001E - Battery Management System

  • Universal for stationery and mobile battery installations
  • Lightweight
  • Easy to use
  • Bright display
  • RF-ID (optional), wireless batery identification
  • Bluetooth (optional) , Headset possible
  • USB (Mini5P) - Interface
  • RS232, compatible to TMC95 users
  • Tech. Datasheet1.1 MB

TMC 2001 RTS - Mobiler Batterietester

  • Messung des metallischen Widerstandes (Rel)
  • Messung des Charge-Transfer Widerstandes (Rct)
  • Spannungsmessung bis zu ± 600VDC
  • Speicherung von 1000000 Datensätzen
  • Komplette Batteriedatenbanken können in das TMC übertragen werden.
  • IrDA-Schnittstelle zur Anbindung eines DMA35-Dichtesensors
  • RF-ID, Batterieidentifikation durch den Einsatz von Transpondern
  • BLUETOOTH Datenschnittstelle, bequemer Einsatz eines Headsets möglich
  • 8 Stunden Betriebsdauer. Leicht auswechselbares Akkupack.

CS-3001 - Battery Test System

  • Easy to operate
  • Expandable up to 120 voltage inputs
  • Block voltage +/- 16,6 VDC
  • 600VDC CAT III (5000 VDC est voltage)
  • Parallel testing of battery systems possible
  • Tech. Datasheet963 kB

TMC – 4001/127 /63 /31

  • the perfect mobile test system for recurring battery tests. In interaction with an electronic load, the condition of a battery system (SOH) can be precisely determined during a capacity test.
  • Battery systems of up to 127 blocks can be tested. If desired, two batteries (with a reduced number of blocks) can be tested. The maximum block voltage is 15V.
  • The test system uses relays with an increased dielectric strength of 3000VDC. In addition, 4 parallel working measuring circuits for block voltage measurement are integrated, which are galvanically separated from each other (5000VDC).

CS-4001PM/127 - Capacity Test System

  • test a single battery of up to 127 x 2V blocks
  • two batteries in parallel
  • max block voltage 15V.
  • Manual821.5 kB
  • Tech. Datasheet1.5 MB

BTS 200 MKII - Batterie Test System

  • High power battery capacity test system
  • Discharging current up to 1300A with external loads (up to 9)
  • Graphical display showing test parameters, curves and results
  • Internal memory
  • Light and easy to carry, with handles and wheels
  • Shunt or clamp metering of an additional current
  • Suitable for all battery types
  • Tech. Datasheet1.1 MB

DMA 35 Standard - Portable Density Meter

  • Measuring range density : 0 - 3 g/cm3
  • Accuracy density: 0.001 g/cm3
  • Repeatability s.d. density: R0.0005 g/cm3
  • Measuring range temperature: 0-40 °C
  • Accuracy temperature : 0.2 °C (0.4 °F)
  • Repeatability s.d. temperature : 0.1 °C (0.2 °F)
  • Tech. Datasheet EN634.5 kB

CM 9010 - Battery-Monitoring-System

  • Intelligent modular battery monitoring
  • Flexible configurable for different applications
  • Continuous online measurement
  • Semiconductor switches (no relays)
  • Best performance /price ratio
  • Tech. Datasheet

DMA 35 V4 Portable Density Meter

  • Patents granted      Smart connection of measuring cell: Patent AT516421 (B1), EP3015847 (B1)
  • Other special functions      Viscosity correction for reliable measurements, also on highly viscous samples
  • Gesture control for easy one-handed measurements
  • Identification of results outside your specified limits
  • Measuring range      Density: 0 g/cm³ to 3 g/cm³
  • Temperature: 0 °C to 40 °C (32 °F to 104 °F)*
  • Sample temperature range      0 °C to 100 °C (32 °F to 212 °F)
  • Accuracy      Density: 0.001 g/cm³ **
  • Temperature: 0.2 °C (0.4 °F)
  • Repeatability, s.d.***      Density: 0.0005 g/cm³
  • Temperature: 0.1 °C (0.2 °F)
  • Reproducibility, s.d.***      Density: 0.0007 g/cm³
  • Resolution      Density: 0.0001 g/cm³
  • Temperature: 0.1 °C (0.1 °F)
  • Ambient temperature****      -10 °C to +50 °C (14 °F to 122 °F)
  • Supported measuring units      
  • Specific gravity
  • Alcohol tables
  • Sugar/extract tables
  • API functions
  • H2SO4 tables
  • Ten programmable custom-specific measuring units
  • Sample volume      2 mL
  • Dimensions (L x W x H)      245 mm x 103 mm x 126 mm

DMA 35 Ex - Portable Density Meter

  • Measuring range:
    • Density: 0 g/cm³ to 3 g/cm³
    • Temperature: 0 °C to 40 °C (32 °F to 104 °F)*
    • Viscosity: 0 mPa·s to 1000 mPa·s
  • Accuracy:
    • Density: 0.001 g/cm³
    • Temperature: 0.2 °C (0.4 °F)
  • Repeatability, s.d.:
    • Density: 0.0005 g/cm³
    • Temperature: 0.1 °C (0.2 °F)
  • Ambient temperature: -10 °C to +50 °C (14 °F to 122 °F)
  • Supported measuring units:
    • Specific gravity
    • Alcohol tables
    • Sugar/extract tables
    • API functions
    • H2SO4 tables
    • Ten programmable custom functions (e.g. H2O2, HCl, CH2O)
  • Sample volume: 2 mL
  • Interfaces: IrDA OBEX/LPT, RFID
  • Intrinsically safe: yes, [Ex] II 2 G Ex ib IIC T4

DMA 35 Ex Petrol -

  • Measuring range:
    • Density: 0 g/cm³ to 3 g/cm³
    • Temperature: 0 °C to 40 °C (32 °F to 104 °F)*
    • Viscosity: 0 mPa·s to 1000 mPa·s
  • Accuracy
    • Density: 0.001 g/cm³
    • Temperature: 0.2 °C (0.4 °F)
  • Repeatability, s.d.
    • Density: 0.0005 g/cm³
    • Temperature: 0.1 °C (0.2 °F)
  • Ambient temperature: -10 °C to +50 °C (14 °F to 122 °F)
  • Supported measuring units:
    • Specific gravity
    • Alcohol tables
    • Sugar/extract tables
    • API functions
    • H2SO4 tables
    • Ten programmable custom functions (e.g. H2O2, HCl, CH2O)
  • Sample volume: 2 mL
  • Interfaces: IrDA OBEX/LPT, RFID
  • Intrinsically safe: yes, [Ex] II 2 G Ex ib IIC T4

Snap 41 Tragbares Alkoholmessgerät für Destillate

  • No manual temperature correction required
  • You will receive the finished result: Values are displayed in% v / v (corrected to 20 ° C and 15 ° C for the Japanese market) or ° Proof (corrected to 60 ° F)
  • Accuracy of 0.2% v / v
  • The influence of viscosity on the density result is corrected automatically
  • Predefined calibration process with deionized water
  • New adjustment routine ensures alcohol measurements with an accuracy of up to 0.2% v / v, even at low measuring temperatures and low alcohol concentrations
  • Tech. Datasheet192 kB

Snap 51 Tragbares Alkoholmessgerät für Destillate

  • The temperature correction of the results takes place automatically: temperature correction tables are not required!
  • The values are displayed in% v / v (corrected to 20 ° C or 15 ° C for the Japanese market) or ° Proof (corrected to 60 ° F)
  • You receive traceable results thanks to the sample identification via RFID (Radio Frequency Identification)
  • You can read the results from the large color display or save and print them out or later transfer them to a PC via Bluetooth
  • You can adjust the alcohol strength of your spirits with an accuracy of 0.1% v / v and save valuable pure distillates
  • It is guaranteed that exactly what is on the label is in the bottle
  • Calibrations and adjustments can easily be carried out with deionized water according to the predefined routine
  • Tech. Datasheet531.7 kB

DMA 500 - digital density meter

  • Measuring range
    • Density 0 g/cm³ to 3 g/cm³
    • Temperature 15 °C to 40 °C (59 °F to 104 °F)
    • Pressure 0 bar to 3 bar (0 psi to 43.5 psi)
  • Accuracy
    • Density 0.001 g/cm³
    • Temperature 0.3 °C
  • Repeatability s.d.
    • Density 0.0002 g/cm³
    • Temperature 0.1 °C
  • Minimum sample volume approx. 1 mL
  • Predefined tables and functions
    • Alcohol tables
    • Sugar/extract tables
    • Acid/base tables
    • API functions
    • Ten programmable custom functions
  • Controls : Softkeys, optional keyboard or bar code reader
  • Interfaces
    • 1 x Bluetooth
    • 2 x USB
    • 1 x Ethernet
  • Internal storage 1000 measured results
  • Weight 2.5 kg (5.5 lbs)
  • Dimensions : (L x W x H) 210 mm x 200 mm x 135 mm
  • Wetted parts PTFE, borosilicate glass
  • Power supply
    • AC 100 - 240 V, 50/60 Hz, 1.4 A
    • DC 12 V, 5 A
  • Rechargeable battery type Li-Ion 7.4 V, 2.25 Ah (optional: Li-Ion 7.5 V, 4.8 Ah)
  • Maximum off-the-line operation 2 hours (6 hours with optional high-performance battery)
  • Tech. Datasheet634.5 kB
ICS SCHNEIDER MESSTECHNIK GmbH
Briesestraße 59,      D-16562 Hohen Neuendorf / OT Bergfelde
  • Tel.:     +49 3303 5040-66
  • Fax:     +49 3303 5040-68
  • E-Mail:     
Home
Sitemap
References
Contact
Impressum
AGB