Battery testers
TMC 2001E - Battery Management System
- Universal for stationery and mobile battery installations
- Lightweight
- Easy to use
- Bright display
- RF-ID (optional), wireless batery identification
- Bluetooth (optional) , Headset possible
- USB (Mini5P) - Interface
- RS232, compatible to TMC95 users
TMC 2001 RTS - Mobiler Batterietester
- Messung des metallischen Widerstandes (Rel)
- Messung des Charge-Transfer Widerstandes (Rct)
- Spannungsmessung bis zu ± 600VDC
- Speicherung von 1000000 Datensätzen
- Komplette Batteriedatenbanken können in das TMC übertragen werden.
- IrDA-Schnittstelle zur Anbindung eines DMA35-Dichtesensors
- RF-ID, Batterieidentifikation durch den Einsatz von Transpondern
- BLUETOOTH Datenschnittstelle, bequemer Einsatz eines Headsets möglich
- 8 Stunden Betriebsdauer. Leicht auswechselbares Akkupack.
CS-3001 - Battery Test System
- Easy to operate
- Expandable up to 120 voltage inputs
- Block voltage +/- 16,6 VDC
- 600VDC CAT III (5000 VDC est voltage)
- Parallel testing of battery systems possible
TMC – 4001/127 /63 /31
- the perfect mobile test system for recurring battery tests. In interaction with an electronic load, the condition of a battery system (SOH) can be precisely determined during a capacity test.
- Battery systems of up to 127 blocks can be tested. If desired, two batteries (with a reduced number of blocks) can be tested. The maximum block voltage is 15V.
- The test system uses relays with an increased dielectric strength of 3000VDC. In addition, 4 parallel working measuring circuits for block voltage measurement are integrated, which are galvanically separated from each other (5000VDC).
CS-4001PM/127 - Capacity Test System
- test a single battery of up to 127 x 2V blocks
- two batteries in parallel
- max block voltage 15V.
BTS 200 MKII - Batterie Test System
- High power battery capacity test system
- Discharging current up to 1300A with external loads (up to 9)
- Graphical display showing test parameters, curves and results
- Internal memory
- Light and easy to carry, with handles and wheels
- Shunt or clamp metering of an additional current
- Suitable for all battery types
DMA 35 Standard - Portable Density Meter
- Measuring range density : 0 - 3 g/cm3
- Accuracy density: 0.001 g/cm3
- Repeatability s.d. density: R0.0005 g/cm3
- Measuring range temperature: 0-40 °C
- Accuracy temperature : 0.2 °C (0.4 °F)
- Repeatability s.d. temperature : 0.1 °C (0.2 °F)
CM 9010 - Battery-Monitoring-System
- Intelligent modular battery monitoring
- Flexible configurable for different applications
- Continuous online measurement
- Semiconductor switches (no relays)
- Best performance /price ratio
DMA 35 V4 Portable Density Meter
- Patents granted Smart connection of measuring cell: Patent AT516421 (B1), EP3015847 (B1)
- Other special functions Viscosity correction for reliable measurements, also on highly viscous samples
- Gesture control for easy one-handed measurements
- Identification of results outside your specified limits
- Measuring range Density: 0 g/cm³ to 3 g/cm³
- Temperature: 0 °C to 40 °C (32 °F to 104 °F)*
- Sample temperature range 0 °C to 100 °C (32 °F to 212 °F)
- Accuracy Density: 0.001 g/cm³ **
- Temperature: 0.2 °C (0.4 °F)
- Repeatability, s.d.*** Density: 0.0005 g/cm³
- Temperature: 0.1 °C (0.2 °F)
- Reproducibility, s.d.*** Density: 0.0007 g/cm³
- Resolution Density: 0.0001 g/cm³
- Temperature: 0.1 °C (0.1 °F)
- Ambient temperature**** -10 °C to +50 °C (14 °F to 122 °F)
- Supported measuring units
- Specific gravity
- Alcohol tables
- Sugar/extract tables
- API functions
- H2SO4 tables
- Ten programmable custom-specific measuring units
- Sample volume 2 mL
- Dimensions (L x W x H) 245 mm x 103 mm x 126 mm
DMA 35 Ex - Portable Density Meter
- Measuring range:
- Density: 0 g/cm³ to 3 g/cm³
- Temperature: 0 °C to 40 °C (32 °F to 104 °F)*
- Viscosity: 0 mPa·s to 1000 mPa·s
- Accuracy:
- Density: 0.001 g/cm³
- Temperature: 0.2 °C (0.4 °F)
- Repeatability, s.d.:
- Density: 0.0005 g/cm³
- Temperature: 0.1 °C (0.2 °F)
- Ambient temperature: -10 °C to +50 °C (14 °F to 122 °F)
- Supported measuring units:
- Specific gravity
- Alcohol tables
- Sugar/extract tables
- API functions
- H2SO4 tables
- Ten programmable custom functions (e.g. H2O2, HCl, CH2O)
- Sample volume: 2 mL
- Interfaces: IrDA OBEX/LPT, RFID
- Intrinsically safe: yes, [Ex] II 2 G Ex ib IIC T4
DMA 35 Ex Petrol -
- Measuring range:
- Density: 0 g/cm³ to 3 g/cm³
- Temperature: 0 °C to 40 °C (32 °F to 104 °F)*
- Viscosity: 0 mPa·s to 1000 mPa·s
- Accuracy
- Density: 0.001 g/cm³
- Temperature: 0.2 °C (0.4 °F)
- Repeatability, s.d.
- Density: 0.0005 g/cm³
- Temperature: 0.1 °C (0.2 °F)
- Ambient temperature: -10 °C to +50 °C (14 °F to 122 °F)
- Supported measuring units:
- Specific gravity
- Alcohol tables
- Sugar/extract tables
- API functions
- H2SO4 tables
- Ten programmable custom functions (e.g. H2O2, HCl, CH2O)
- Sample volume: 2 mL
- Interfaces: IrDA OBEX/LPT, RFID
- Intrinsically safe: yes, [Ex] II 2 G Ex ib IIC T4
Snap 41 Tragbares Alkoholmessgerät für Destillate
- No manual temperature correction required
- You will receive the finished result: Values are displayed in% v / v (corrected to 20 ° C and 15 ° C for the Japanese market) or ° Proof (corrected to 60 ° F)
- Accuracy of 0.2% v / v
- The influence of viscosity on the density result is corrected automatically
- Predefined calibration process with deionized water
- New adjustment routine ensures alcohol measurements with an accuracy of up to 0.2% v / v, even at low measuring temperatures and low alcohol concentrations
Snap 51 Tragbares Alkoholmessgerät für Destillate
- The temperature correction of the results takes place automatically: temperature correction tables are not required!
- The values are displayed in% v / v (corrected to 20 ° C or 15 ° C for the Japanese market) or ° Proof (corrected to 60 ° F)
- You receive traceable results thanks to the sample identification via RFID (Radio Frequency Identification)
- You can read the results from the large color display or save and print them out or later transfer them to a PC via Bluetooth
- You can adjust the alcohol strength of your spirits with an accuracy of 0.1% v / v and save valuable pure distillates
- It is guaranteed that exactly what is on the label is in the bottle
- Calibrations and adjustments can easily be carried out with deionized water according to the predefined routine
DMA 500 - digital density meter
- Measuring range
- Density 0 g/cm³ to 3 g/cm³
- Temperature 15 °C to 40 °C (59 °F to 104 °F)
- Pressure 0 bar to 3 bar (0 psi to 43.5 psi)
- Accuracy
- Density 0.001 g/cm³
- Temperature 0.3 °C
- Repeatability s.d.
- Density 0.0002 g/cm³
- Temperature 0.1 °C
- Minimum sample volume approx. 1 mL
- Predefined tables and functions
- Alcohol tables
- Sugar/extract tables
- Acid/base tables
- API functions
- Ten programmable custom functions
- Controls : Softkeys, optional keyboard or bar code reader
- Interfaces
- 1 x Bluetooth
- 2 x USB
- 1 x Ethernet
- Internal storage 1000 measured results
- Weight 2.5 kg (5.5 lbs)
- Dimensions : (L x W x H) 210 mm x 200 mm x 135 mm
- Wetted parts PTFE, borosilicate glass
- Power supply
- AC 100 - 240 V, 50/60 Hz, 1.4 A
- DC 12 V, 5 A
- Rechargeable battery type Li-Ion 7.4 V, 2.25 Ah (optional: Li-Ion 7.5 V, 4.8 Ah)