ICS-Schneider Messtechnik GmbH
  • Deutsch
  • English
  • Products
  • Company
    • About Us
    • Jobs & Carrers
    • Calibration
  • News
    • News
    • Sale actions
  • Downloads
  • Contact

Products

  • Manometer / Gauges / Accessories
  • Thermometer / Temperature sensors
  • Pressure and Temperature switches
  • Pressure sensors / Transmitter / diff. Pressure sensors / Level sensors
  • Flowsensors / Waysensors / Powersensors / Waagen
  • Humiditysensors / Velocitysensors
  • Calibrators, Test kits
  • Calibration pumps
  • Pressure controller
  • Pressure meters
  • Temperature meters / Thermography
  • Gas meters and Gas sensors
  • Dataloggers and Measuring systems
  • Minimess
  • Analog meters/ Digital meters / Current Voltage transformers / Transducers / Buffer
  • Network equipment
  • Dynisco products
  • Energy meters / VDE check equipment
    • Voltage testers
    • Clamp meters / Flexible transducers
    • Analog / Digital multimeters
    • Resistance meters / Microohm meters
    • Power and energy meters / Network meters
    • VDE Hardware checker / VDE 0100 / VDE 0701-0702 / VDE 0113
    • Isolation meters
    • Grounding test measurer
    • Welding units - Tester
    • Tester energy supply
    • Battery testers
    • Oscilloscope
    • Laser rangefinder / Cable altimeters
    • Illumination meters / Thickness meters / Wall thickness / Rotation speed meters / Soundlevel / Field intensity
    • Photovoltaics equipment
  • Home
  • Products
  • Energy meters
  • Isolation meters

Isolation meters

C.A 6501 - Hand-cranked portable insulation tester

  • Test voltage: 500 V DC
  • Measurement range: 0.5 to 200 MΩ
  • Resistance measurement: 45 to 500 kΩ
  • Continuity measurement
  • Power supply: magneto
  • Protection: IP52
  • Electrical safety: IEC 61010 300V CAT III
  • Dimensions: 120 x 120 x 130 mm / 1.06 kg
  • Tech. Datasheet733.6 kB

C.A 6503 - 250/500/1,000 V hand-cranked analogue insulation tester

  • Test voltages: 250, 500 and 1,000 V DC
  • Measurement range: 1 to 5,000 MΩ
  • Power supply: magneto
  • Protection: IP52
  • Electrical safety: IEC 61010 300V CAT III
  • Dimensions : 120 x 120 x 130 mm / 1.06 kg
  • Tech. Datasheet733.6 kB

CA 6511 - Simple testing of industrial and domestic electrical installations

  • insulation: up to 1,000MΩ (1 cal.) at 500V DC
  • AC voltage: 0 to 600V
  • continuity: -10Ω to +10Ω (I=200mA)
  • automatic testing of absence of voltage by direct measurement
  • single input on two colour-coded terminals
  • highly readable display and logarithmic scale
  • measurement in compliance with IEC 61557, NF C 15-100, IEC 364, VDE 0413 and BS 7671
  • electrical safety: IEC 1010 600V Cat III-2
  • dimensions: 167 x 106 x 55mm; weight: 600g
  • Tech. Datasheet676.2 kB

CA 6513 - Simple testing of industrial and domestic electrical installations

  • insulation: up to 1,000MΩ (1 cal.) at 500V and 1,000V DC
  • AC voltage: 0 to 600V
  • resistance: 0 to 1,000Ω
  • continuity: -10Ω to +10Ω (I=200mA)
  • automatic testing of voltage absence by direct measurement
  • single input on two colour-coded terminals
  • highly readable display and logarithmic scale
  • measurement in compliance with IEC 61557, NF C 15-100, IEC 364, VDE 0413 and BS 7671
  • electrical safety: IEC 1010 600V Cat. III-2
  • dimensions: 167 x 106 x 55mm; weight: 600g
  • Tech. Datasheet676.2 kB

C.A 6522 - 1 kV Insulation and Continuity Tester

  • 1 kV Insulation and Continuity Tester
  • Industrial maintenance
  • 40 GΩ / Test voltage 250-500-1,000 V
  • Manual / Lock / Duration modes
  • Continuity, Voltage
  • Tech. Datasheet_EN907.7 kB

C.A 6524 - 1 kV Insulation and Continuity Tester

  • 1 kV Insulation and Continuity Tester
  • Industrial maintenance
  • 200 GΩ
  • Test voltage: 50-100-250-500-1 000 V
  • Manual / Lock / Duration modes, PI / DAR ratios
  • Alarms, ∆REL
  • Tech. Datasheet_EN907.7 kB

C.A 6526 - 1 kV Insulation and Continuity Tester

  • 1 kV Insulation and Continuity Tester
  • Industrial maintenance
  • 200 GΩ
  • Test voltage: 50-100-250-500-1,000 V
  • Manual / Lock / Duration modes, PI / DAR ratios
  • Continuity, Voltage, Capacitance
  • Alarms, ∆REL
  • Tech. Datasheet_EN907.7 kB

C.A 6532 - Communicating 50-100 V Telecom Insulation and Continuity Tester

  • Communicating 50-100 V Telecom Insulation and Continuity Tester
  • 20 GΩ, Test voltage: 50-100 V
  • Continuity, Voltage, Frequency, Capacitance
  • Distance = f(C)
  • Storage, Communication
  • Tech. Datasheet_EN907.7 kB

C.A 6534 - Communicating Insulation and Continuity Tester for Electronics Applications

  • Communicating Insulation and Continuity Tester for Electronics Applications
  • 50 GΩ
  • Test voltage : 10-25-100-250-500 V
  • Manual / Lock / Duration modes
  • Alarms, ∆REL
  • Continuity, Voltage
  • Storage, Communication
  • Tech. Datasheet_EN907.7 kB

C.A 6536 - Insulation and Continuity Tester for Special Applications

  • Insulation and Continuity Tester for Special Applications
  • 20 GΩ
  • Test voltage : 10 to 100 V - 1 V increments
  • Manual / Lock / Duration modes
  • Alarms, ∆REL
  • Continuity, Voltage, Resistance
  • Magnetic mounting
  • Tech. Datasheet_EN907.7 kB

MX 407 - 1,000 V insulation tester - multimeter

  • Insulation at 250 V / 500 V / 1,000 V
  • Voltage from 0 to 600 VAC/DC
  • Continuity from 0 to 400 Ω (I > 200 mA)
  • Resistance from 0 to 400 kΩ
  • Automatic detection if a voltage is present
  • Power supply: 6 x LR6 1.5V batteries
  • Compliant with IEC 61557 -3 -4
  • IEC 61010 600 V CAT IV
  • Dimensions: 200 x 92 x 50 mm / 700 g
  • Tech. Datasheet1.2 MB

CA 6541 - high-performance 50V to 1kV insulation tester

  • insulation: up to 4TΩ (5 cal.) at 50/100/250/500 and 1,000V DC
  • automatic calculation of insulation quality ratios: DAR and PI
  • programmable test period and plotting of the R(t) curve (automatic memorisation of 20 samples)
  • automatic indication of voltage before and after measurement: 1 to 1000V AC/DC
  • resistance: from 0.01Ω to 400kΩ
  • continuity: 0.01Ω to +40Ω (audible beep and lead compensation)
  • automatic measurement capacity after each insulation measurement: 0.005 to 4.999 µF
  • microprocessor-controlled
  • giant LCD screen with digital display + bargraph
  • backlit display
  • SMOOTH function (smoothing of values displayed)
  • insulation test voltages can be locked
  • programmable alarms
  • long battery life: 8 x LR14 batteries (21,000 insulation tests of 5s each)
  • remote control probe available as an option
  • electrical security: IEC 61010-1 + A2 – Cat. III - 600V and IEC 61557
  • dimensions: 240 x 185 x 110mm; weight: 3.4kg
  • Tech. Datasheet1.4 MB

CA 6543 - high performance insulation tester

  • insulation: up to 4TΩ (5 cal.) at 50/100/250/500 and 1,000V DC
  • automatic calculation of insulation quality ratios: DAR and PI
  • programmable test period and plottingof the R(t) curve
  • automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC
  • resistance: 0.01Ω to 400kΩ
  • continuity: 0.01Ω to +40Ω (audible beep and lead compensation )
  • automatic capacitance measurement after each insulation measurement: 0.005 to 4.999µF
  • microprocessor-controlled
  • memorisation of measurements (128KB)
  • bi-directional RS232
  • giant LCD screen with digital display + bargraph
  • backlit display
  • SMOOTH function (smoothing of values displayed)
  • possibility of locking insulation test voltages
  • programmable alarms
  • long battery life due to rechargeable battery with built-in charger
  • remote control probe available as an option
  • electrical safety: IEC 61010-1 + A2 - Cat. III - 600V and IEC 61557
  • dimensions: 240x185x110mm; weight: 3.4kg
  • wide range of accessories available as an option: remote control probe, MegohmView software for processing the data on a PC, printer.
  • Tech. Datasheet1.4 MB

C.A 6505 - 5 kV digital insulation tester for use in the field

  • Fixed 500/1,000/2,500/5,000 V DC test voltage or programmable from 40 V to 5,100 V DC
  • Measurement range: 10 kΩ to 10 TΩ
  • Programmable test duration
  • Calculation of DAR & PI quality ratios
  • Measurement of voltage, capacitance and leakage current
  • LCD screen with bargraph
  • Power supply by NiMh rechargeable battery
  • Compliant with IEC 61557
  • IP53 protection
  • IEC 61010 1,000 V CAT III safety
  • Dimensions: 270 x 250 x 180 mm / 4.3 kg
  • Tech. Datasheet848.1 kB

CA 6545 - Megohmmeter

  • wide range from 30kΩ to 10TΩ !
  • 4 fixed test voltages: 500/1,000/2,500 and 5,000V
  • programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
  • giant backlit LCD screen with digital display + bargraph
  • qualitative analysis: automatic calculation of DAR, PI and DD (dielectric discharge) ratios and tracing of the R(t) curve
  • numerous functions: programmed test duration, lock-in of test voltage, smooth function, programmable alarms, etc.
  • power supply: rechargeable NiMH battery with a 30-day service life for 10 DAR measurements and 5 PI measurements per day
  • electrical safety: IEC 61010-1 Cat.III 1,000V or Cat.I 2,500V and 61557
  • dimensions: 270x250x180mm; weight: 4.3kg
  • Tech. Datasheet239.4 kB

CA 6547 - Megohmmeter

  • wide range from 30kΩ to 10TΩ !
  • 4 fixed test voltages: 500 / 1,000 / 2500 and 5,000V
  • programmable test voltage position: from 40 to 5,100V in increments of 10V or 100V
  • giant backlit LCD screen with digital display + bargraph
  • qualitative analysis of insulation: automatic calculation of DAR, PI and DD (dielectric discharge) ratios and plotting of the R(t) curve
  • numerous functions: programmable test duration, lock-in of test voltage, smooth function, programmable alarms, etc.
  • memorisation of several thousand measurements
  • RS 232 connector for link-up to a PC (MEGΩVIEW processing software)
  • Tech. Datasheet239.4 kB

CA 6549 - Insulation at 5kV on graphic screen

  • measurement range: 10kΩ to 10TΩ!
  • 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
  • adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
  • step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
  • DAR, PI and DD quality ratios calculated automatically
  • programmable test length and R(t) measurement curve displayed directly on the screen
  • with indication of measurement t° after measurement, resistance recalculated to reference temperature for reliable and accurate insulation monitoring
  • many other functions: test voltage locking, smooth function, programmable alarms, etc.
  • can record thousands of measurements
  • RS 232 connector for connection to PC or very compact serial printer
  • power supply: rechargeable NiMH battery for 30 days' operating with 10 DAR measurements and 5 PI measurements per day
  • electrical safety: IEC 61010-1 Cat.III 1,000V or Cat.I 2,500V and 61557
  • dimensions: 270x250x180mm; mass: 4.3kg
  • Tech. Datasheet239.4 kB

C.A 6550 - 10 kV Insulation Tester

  • Wide measurement range from 10 kohm to 25 Tohm
  • Fixed or programmable test voltage from 40V to 10 kV
  • 5mA max charging current
  • Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
  • Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
  • Multiple test modes: voltage ramp and step with "burning", "early break" and "I-limit" modes
  • 3 filters to optimize measurement stability
  • Calculation of R at a reference temperature
  • 80,000-measurement storage capacity and real-time clock
  • Optically-isolated USB communication for transfer onto PC and report generation with DataView® software
  • Tech. Datasheet1.2 MB

C.A 6555 - insulation tester at up to 15 kV

  • Wide measurement range from 10 kohm to 30 Tohm
  • Fixed or programmable test voltage from 40V to 15 kV
  • 5mA max. charging current
  • Large backlit LCD screen with digital display, bargraph and R(t)+u(t), i(t) and i(u) graphs
  • Automatic ratio calculation: DAR / PI / DD / DR (ppm/V)
  • Multiple test modes: voltage ramp and step with "burning", "early break" and "I-limit" modes
  • 3 filters to optimize measurement stability
  • Calculation of R at a reference temperature
  • 80,000-measurement storage capacity and real-time clock
  • Optically-isolated USB communication for transfer onto PC and report generation with DataView® software
  • Tech. Datasheet1.2 MB

M70 - Hand held meter for Insulation and Continuity of earth conductors measurements

  • Insulation with test voltage 250, 500, 1000VDC
  • Up to 4Gohm measurement range
  • Automatic discharge of device under test
  • LOCK feature for continuous measurements
  • Programmable timer up to 60s
  • Continuity of earth conductors with test current of 200mA
  • Automatic test leads calibration
  • A/DC voltage up to 600V
  • Resistance and continuity test with buzzer
  • Bargraph and backlight
  • AutoPowerOFF
  • Low battery indication
  • Protection rubber holster
  • Tech. Datasheet246 kB

M72 - Portable meter for insulation/continuity tests and TRMS integrated multimeter

  • Insulation Resistance measurement with 250, 500VDC
  • Measurement range up to 1Gohm
  • Automatic discharging object after test
  • Continuity test of protective conductors with 200mA
  • Auto calibration of test leads
  • DC Voltage
  • AC TRMS Voltage
  • Automatic detection of AC/DC signals
  • AC TRMS Current with optional external clamp
  • AC TRMS Leakage current with optional external clamp
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with optional external clamp
  • Phase sequence indication at 1 or 2 wires method
  • Phase coincidence indication at 1 or 2 wires method
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function
  • Auto Power OFF
  • Tech. Datasheet267.3 kB

ISO 410 - Meter for Insulation test and Continuity of earth conductor test with use of remote probe

  • Continuity test with 200mA
  • Insulation with 50, 100, 250, 500, 1000VDC
  • Measure with remote probe (PR400 optional accessory)
  • Contextual help at display
  • Internal memory
  • Optical-USB interface with PC connection
  • Tech. Datasheet370.9 kB

HT7051 - Professional insulation meter with test voltage programmable up to 5kVDC

  • Insulation resistance measurement with test voltage up to 5kVDC
  • Measurement range up to 10Tohm
  • FIX mode with test voltage of 100, 250, 500, 1k, 2.5k e 5kVDC
  • ADJUST mode with test voltage selectable from 100 to 5kVDC
  • RAMP mode with selectable duration time and test voltage
  • Selection of 3 type of ramp test
  • Polarization Index (P.I.) measurement
  • Dielectric Absorption Ratio (D.A.R) measurement
  • DC/AC TRMS voltage up to 600V
  • SMOOTH feature for stable measurement results
  • GUARD test lead for surface leakage current compensation
  • MX, MIN limit selectable threshold on measurements
  • Automatic discharging of device under test
  • Fuse protection on power supply
  • LCD display with backlight and bargraph
  • Internal memory for saving results
  • Recall saved results at display
  • RS-232 interface for PC connection
  • Rechargeable internal battery
  • Tech. Datasheet298.9 kB

HT 7052 - Professional insulation meter with test voltage up to 10KV DC

  • DC test voltage measuring range 500V ÷ 10kV
  • Insulation resistance measuring range 120kΩ ÷ 10TΩ
  • Dielectric strength in DC
  • Test with programmable ramp steps of 25VDC
  • Programmable test timer 1s ÷ 30min
  • Setting of measurement limit value
  • Measurement of polarization index P.I.
  • Measurement of dielectric absorption ratio D.A.R.
  • Measurement of dielectric discharge ratio D.D.
  • Measurement of discharge capacity
  • Automatic discharge of target
  • Measurement of DC/AC voltage up to 600V
  • RS232/optical/USB interface for transferring data onto the PC<7li>
  • EMC 2004/108/CE Directive
  • LVD 2006/95/CE Directive
  • IEC/EN 61010-1
  • IEC/EN61557-1
  • IEC/EN61557-2
  • CE MARK
  • EMC: IEC/EN61326
  • Tech. Datasheet428 kB

OMegaSafe ISO 1Ex - Compact megohmmeter for potentially explosive atmospheres

  • Safe and universal between 1 k Ω and 2 TΩ
  • Test voltage 32, 100, 500 V
  • Indication of external voltage and integrated voltage indication up to 500 V
  • Push-button for rapid discharge of capacitances
  • Measuring range: 1k ... 1999 GΩ
  • Test voltage: 32, 100, 500 V
  • Power supply: 9V - 6LR61
  • Acoustic signal: Yes
  • Protection category: IP 65
  • Tech. Datasheet927.2 kB