ICS-Schneider Messtechnik GmbH
  • Deutsch
  • English
  • Products
  • Company
    • About Us
    • Jobs & Carrers
    • Calibration
  • News
    • News
    • Sale actions
  • Downloads
  • Contact

Products

  • Manometer / Gauges / Accessories
  • Thermometer / Temperature sensors
  • Pressure and Temperature switches
  • Pressure sensors / Transmitter / diff. Pressure sensors / Level sensors
  • Flowsensors / Waysensors / Powersensors / Waagen
  • Humiditysensors / Velocitysensors
  • Calibrators, Test kits
  • Calibration pumps
  • Pressure controller
  • Pressure meters
  • Temperature meters / Thermography
  • Gas meters and Gas sensors
  • Dataloggers and Measuring systems
  • Minimess
  • Analog meters/ Digital meters / Current Voltage transformers / Transducers / Buffer
  • Network equipment
  • Dynisco products
  • Energy meters / VDE check equipment
    • Voltage testers
    • Clamp meters / Flexible transducers
    • Analog / Digital multimeters
    • Resistance meters / Microohm meters
    • Power and energy meters / Network meters
    • VDE Hardware checker / VDE 0100 / VDE 0701-0702 / VDE 0113
    • Isolation meters
    • Grounding test measurer
    • Welding units - Tester
    • Tester energy supply
    • Battery testers
    • Oscilloscope
    • Laser rangefinder / Cable altimeters
    • Illumination meters / Thickness meters / Wall thickness / Rotation speed meters / Soundlevel / Field intensity
      • Illumination meters
      • Rotation speed
      • Field intensity
      • Soundlevel
      • Thickness meters / Wall thickness
    • Photovoltaics equipment
  • Home
  • Products
  • Energy meters
  • Illumination meters

Illumination meters

MAVOSPEC BASE - The Spectrometer For Practitioners

  • Measuring functions Illuminance 10 lx to 100 000 lx
  • Measuring ranges Color rendering index Ra, R1 - R15
  • Correlated color temperature per CIE 13.3
  • Duv
  • Peak wavelength
  • Dominant wavelength
  • Purity per CIE 15
  • Chromaticity coordinates [x,y] per CIE 1931
  • Chromaticity coordinates [u',v'] per CIE 1976
  • Chromaticity coordinates [u, v] per CIE 1960
  • Flicker index, %, frequency
  • Spectral range 380 - 780 nm (VIS)
  • Physical resolution ~ 1.8 nm
  • Reproducibility 0.5 nm
  • Integration time 10 ms – 3000 ms
  • Functions Flicker compensation, temperature sensor and automatic zero-point correction
  • Interface USB 2.0
  • Interface protocol Disclosed
  • Memory 4 GB Micro SD in battery compartment
  • Memory mode Manual, auto
  • Data format CSV
  • Mains power pack 100…240 V (50/60 Hz) 0.15A
  • Ausgang USB Buchse 5 V, 1 A
  • Rechargeable battery Li-Ion 3.7 V - 890 mAh, replaceable
  • Rechargeable battery life > 8 hours continuous operation
  • Charging time approx.. 1.5 hours
  • Dimensions 139 x 60 x 30 mm
  • Weight approx. 200 g
  • Scope of delivery Aluminium case, wallet, rechargeable battery, USB cable, power pack, carrying strap, 4 GB micro SD card, instructions
  • Tech. Datasheet1.4 MB

MAVOLUX 5032C/B USB - high precision luxmeter

  • Accuracy class per DIN 5032-7
    • Mavolux 5032 C USB : Class C
    • Mavolux 5032 B USB : Class B
  • Light sensor : Silicon fotodiode with V(λ)-filter
  • Functions :
    • Luminous intensity 10 to 190 000 lx , Autorange, Range Hold, Manual Range, displays Lux (lx)/ Footcandle (fc), Hold function and Max function for display.
  • Measuring range Mavolux 5032 C USB
    • 0.1 lx to 199 900 lx and 1 cd/m² to 1 999 000 cd/m² in 4 ranges (with Luminance Attachment)
  • Measuring range Mavolux 5032 B USB
    • 0.01 lx to 199 900 lx and 0.1 cd/m² to 1 999 000 cd/m² in 5 ranges (with Luminance Attachment)
  • Measurement rate : 2 measurements per second
  • Tech. Datasheet464.1 kB

Mavo-Monitor USB

  • Measuring Ranges: 0,01 cd/m² to 19 990 cd/m² subdivided in 4 measuring ranges
  • Resolution :
    • MR I 0.01 cd/m²
    • MR II 0.1 cd/m²
    • MR III 1 cd/m²
    • MR IV 10 cd/m²
  • Measuring Rate: 2 measurements/sec.
  • Display: Digital, 3 ½ digits LCD
  • Accuracy: Classified according DIN 5032-7, Class B
  • Standard supply: Luminance meter in transport case, Adapter disk, gLux Software incl. meter driver, USB cable, battery and instruction manual

MAVO - SPOT 2 USB

  • Measuring angle : 1°
  • Accuracy:
    • Class B according to DIN 5032-7 in all chapters and DIN EN 13032-1, Appendix B
  • Optical system : Stray light error ambient light (fs (u) < 2%)
  • Field of view : 15° diagonal
  • Focusing distance : 1 m to infinity - focusing with external ring at the lens
  • Light sensor : Silicon photo diode with V() filter (f1 < 3%)
  • Luminance measuring unit : cd/m² or fL (selectable with DIP switches)
  • Measuring ranges :
    • Automatic measuring range selection 0.01 cd/m² to 99 990 cd/m² in four ranges or 0,003 fL to 29 187 fL in four ranges
  • Measuring functions
    • Luminance in cd/m² or fL (selectable)
    • Luminance percentage
    • Memory MEM
    • Correction Factor CORR
    • Measuring the illuminance (Lux) with GOSSEN Reflexion
    • Standard ( optional accessory)
  • Tech. Datasheet258.9 kB

CA 811 - lightmeter

  • 3½-digit display (2,000 counts)
  • measurement range: 20 to 20,000 lux
  • measurement by silicon photodiode
  • resolution: 0.01 lux
  • functions: HOLD / Backlighting / lux or fc /Max
  • accuracy ±3%R + 10 counts
  • I.E.C. spectral correction and incidence correction
  • remote-controlled probe for all types of measurements
  • shockproof protective sheath
  • dimensions: 173 x 60.5 x 38mm - weight: 214g
  • Tech. Datasheet332.2 kB

CA 813 - Luxmeter

  • 3½ -stellige Anzeige (2000 Digit)
  • Messbereich: 20 lx bis 200 000 lx
  • Auflösung: 0,01 lx
  • Messung durch Silizium-Fotodiode
  • HOLD- und PEAK-Funktion, Anzeigebeleuchtung, Anzeige in lx oder fc
  • Genauigkeit ±3%Anz.+ 10 Digit
  • C.I.E.-Spektralkorrektur und Einfallswinkel-Korrektur
  • Abnehmbare Messzelle für vielseitige Messungen
  • Stoßschutz-Hülle
  • Abmessungen: 173 x 60,5 x 38 mm - Gewicht: 223 g
  • Tech. Datasheet332.2 kB

testo 540 - Lux Meter

  • Hold function and max./min. values
  • Incl. calibration protocol
  • Protective cap for safe storage
  • Including wrist strap and belt holder
  • Sensor adapted to spectral sensitivity of the eye
  • Display light
  • Storage temperature : -40 to +70 °C
  • Operating temperature : 0 to +50 °C
  • Battery type : 2 batteries Type AAA
  • Battery life : 200 h
  • Weight : 95 g
  • Dimensions : 133 x 46 x 25 mm

HT204 - Portable digital sun irradiation meter

  • Power sun irradiation up to 2000W/m2
  • Manual zeroing with trimmer
  • Manual range of measurement
  • Silicon photodiode sensor
  • MAX/MIN function
  • Data Hold function
  • Selection between W/m2 and BTU/(ft2*h)
  • Low battery indication
  • Tech. Datasheet80.1 kB

HT307 - Digital Luxmeter with built-in photo sensor and analogical DC output

  • Illumination measurement up to 200 klux (20 kfc)
  • Manual zeroing with trimmer
  • Correction of spectral response
  • Manual range of measurement
  • MAX/MIN function
  • Data Hold function
  • DC analogue output (mV)
  • Selection between lux or ft measurement mode
  • Low battery indication
  • Tech. Datasheet210.8 kB

HT309 - Digital luxmeter with illuminance measurement of LED sources

  • Illumination measurement (Lux/Fc)
  • Illumination measurement of LED sources
  • Correction factors depending on the spectral response
  • Luminous intensity measurement (Cd)
  • Measurement range up to 400kLux
  • Digital adjustment
  • Autorange
  • Data HOLD
  • MAX/MIN/AVG
  • Internal memory
  • Selection between units
  • Auto Power OFF
  • Tech Datasheet189 kB