ICS-Schneider Messtechnik GmbH
  • Deutsch
  • English
  • Products
  • Company
    • About Us
    • Jobs & Carrers
    • Calibration
  • News
    • News
    • Sale actions
  • Downloads
  • Contact

Products

  • Manometer / Gauges / Accessories
  • Thermometer / Temperature sensors
  • Pressure and Temperature switches
  • Pressure sensors / Transmitter / diff. Pressure sensors / Level sensors
  • Flowsensors / Waysensors / Powersensors / Waagen
  • Humiditysensors / Velocitysensors
  • Calibrators, Test kits
  • Calibration pumps
  • Pressure controller
  • Pressure meters
  • Temperature meters / Thermography
  • Gas meters and Gas sensors
  • Dataloggers and Measuring systems
  • Minimess
  • Analog meters/ Digital meters / Current Voltage transformers / Transducers / Buffer
  • Network equipment
  • Dynisco products
  • Energy meters / VDE check equipment
    • Voltage testers
    • Clamp meters / Flexible transducers
    • Analog / Digital multimeters
    • Resistance meters / Microohm meters
    • Power and energy meters / Network meters
    • VDE Hardware checker / VDE 0100 / VDE 0701-0702 / VDE 0113
      • VDE 0100 / VDE 0113
      • VDE 0701-0702
    • Isolation meters
    • Grounding test measurer
    • Welding units - Tester
    • Tester energy supply
    • Battery testers
    • Oscilloscope
    • Laser rangefinder / Cable altimeters
    • Illumination meters / Thickness meters / Wall thickness / Rotation speed meters / Soundlevel / Field intensity
    • Photovoltaics equipment
  • Home
  • Products
  • Energy meters
  • VDE Hardware checker
  • VDE Hardware checker (VDE 0100 / VDE 0113)

VDE Hardware checker (VDE 0100 / VDE 0113)

CA 6113 - Multi-function installation tester

The C.A 6113 is an ALL-IN-ONE instrument for testing electrical installations in compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, FD C 16-600, etc). It combines design, ergonomics, simplicity, performance, rapidity and accuracy.

Suitable for all neutral systems (TT, TN, IT), it is ideal for all sectors: industry, tertiary and residential.

Ergonomics

The rugged, compact C.A 6113 is specially designed for quick and effective familiarization. On its large backlit B&W graphical screen, users can view all the crucial results at a glance.

A rotary switch on the front of the instrument gives direct access to all the functions. A large number of audio and visual symbols are available for quick interpretation of of the results according to the standards.

The contextual help for each function guides the user step-by-step or only when required. The high-performance C.A 6116 offers excellent measurement stability, even in disturbed industrial environments.

C.A 6116N - Multi-function installation tester with data storage

  • Installation testing according to the international standards (IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600, etc.)
  • Quick operation and simple access to measurements
  • User-friendly with its extra-wide backlit graphic screen
  • Excellent measurement stability, including in industrial environments affected by disturbances
  • Simple, reliable connections
  • Contextual help for each function
  • Suitable for all types of neutral systems (TT, TN, IT)
  • Customized, hierarchical storage of measurement results
  • Tech. Datasheet3 MB

C.A 6117 - Multi-function installation tester with advanced features: type-B RCD testing, voltage drop, built-in fuse table and storage

The C.A 6117 is an ALL-IN-ONE instrument for testing electrical installations in compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, FD C 16-600, etc). It combines design, ergonomics, simplicity, performance, rapidity and accuracy.

Suitable for all neutral systems (TT, TN, IT), it is ideal for all sectors: industry, tertiary and residential.

Ergonomics

The rugged, compact C.A 6117 is specially designed for quick and effective familiarization. On its large LCD graphical colour display with backlighting, users can view all the crucial results at a glance.

A rotary switch on the instrument’s front panel gives direct access to all the functions. A large number of visual symbols and audio signals help with quick interpretation of the results in accordance with the standards. The on-line contextual help menus can guide the user step by step, if needed. The storage capacity can save up to 1,000 tests. The C.A 6117 also has a USB output for data transfer.

Measurements

The high-performance C.A 6117 offers excellent measurement stability, even in disturbed industrial environments. All the measurements needed to test an electrical installation are available: continuity, resistance, insulation, earth and selective earth, loop impedances, type A and AC RCDs. The C.A 6117 can also be used to measure voltage, frequency, current via a clamp, active power, harmonics and phase rotation.

The C.A 6117 is also fitted with type-B RCD testing, built-in fuse table and voltage drop feature.

Designed and manufactured in France, the C.A 6117 was developed in compliance with eco-design procedures.

Analysis of the results

The measurements made with the C.A 6117 can be processed by the DataView® multi-product expert processing software. DataView® automatically recognizes the instrument when it is connected to the PC and opens the corresponding menu. By means of a tree structure, it offers users direct access to the data recorded in the instrument, its configuration, etc.

It is equipped with multiple predefined report templates which comply with the standards' requirements. Users can also create their own templates, as required.

Delivered as standard, the ICT software offers the following functions for quick, simplified analysis of the recorded measurements: recovery of the data, configuration of the instrument, customization of measurement campaigns with transfer into the instrument and generation of reports.

Combi G2 - Advanced multifunction installation tester for verification of electric safety of private and industrial electric systems

  • All verifications of electric safety provided for by standards IEC/EN61557-1.
  • Advanced Loop Verification of magnetothermal protections, fuses and cable sizes.
  • Measurement of electric parameters insingle- phase installations (V,I, W, VAR, VA, PF).
  • Test of RCDs type A, AC, B up to 1A, also with separate clamp jaws with test current up to 10A (with optional accessory RCDX10).
  • Measurement of insulation resistance.
  • Measurement of continuity of protection conductors.
  • Verification of phase sequence (SEQ) and leakage currents.
  • Measurement of environmental paramemeters with external probes.

COMBI G3 - VDE 0100 Professional multi-function electrical safety tester

  • Continuity of protection conductors with 200mA
  • Insulation resistance with 50, 100, 250, 500,1000V DC
  • Type A, AC, and B general, selective, and delayed RCDs up to 1000mA
  • Line/fault impedance with prospective short circuit current calculation
  • High resolution line/fault impedance (with IMP57 optional accessory)
  • Curve B, C, D, and K MCBs and type gG and aM fuses
  • Selection of length, type, and insulation of the cable under test
  • Selection of tripping time of the protection device under test
  • Earth resistance and soil resistivity with auxiliary rods
  • Earth ground resistance (with T2100 optional accessory)
  • Non-trip earth loop impedance
  • Phase sequence indication
  • Leakage current by means of the external transducer HT96U (optional)
  • Environmental parameters (C/F, HR%, Lux) by means of optional probes
  • TFT display with touch-screen
  • Help on-line
  • Internal memory
  • USB interface to connect to the PC
  • Wi-Fi (optional) interface to connect to PDAs, smart phones, etc.
  • Rechargeable NiMH batteries (external battery charger)
  • Tech. Datasheet431.5 kB

GSC60 - Professional safety tester and network analyzer

  • Touchscreen colour display
  • Integrated WiFi connection and compatibility with HTANALYSIS App
  • Continuity of protective circuit with 200mA
  • Insulation with voltage 50, 100, 250, 500, 1000VDC
  • Time/Current tripping of A, AC General, Selective and Delayed RCDs up to 1000mA
  • Time/Current tripping of type B RCDs up to 300mA
  • Tripping time and current of RCDs with separate clamp jaws type B, A, AC Standard, Selective and Delayed up to 10A
  • Loop impedance P-N, P-P, P-PE and calculation of prospective short-circuit current
  • Line/Loop impedance with high resolution (with optional accessory IMP57)
  • Percentage voltage drop on the line
  • Measurement and recording of leakage currents and environment parameters
  • Three-phase Power quality and Energy consumption analysis:
  • 9 types of electrical systems 1Φ-2wires, 1Φ-split phase, 3Φ-3 wires, 3Φ-Aron, 3Φ-Open Δ, 3Φ-Open Y, 3Φ-2 el. 1/2, 3Φ-4 wires Y, 3Φ-High Leg.
  • 632 parameters can be recorded for over two months
  • Voltage Anomalies (dips and peaks) with a resolution of 20ms @50Hz
  • Measurement/recording of Active, Reactive, Apparent Power
  • Measurement/recording of Active, Reactive, Apparent Energy
  • Measurement/recording of Cosphi, Power Factor
  • Measurement/Recording of Voltage and Current Harmonics up to 49th with THD%
  • Voltage/current vector diagram
  • Voltage/current waveforms
  • Tables or histograms of Harmonics and THD%
  • Summary table of main electric parameters
  • Help on line on the display
  • Protection category CAT IV

Fluke 1653B - Multifunction Installation Tester (VDE 0100/0413)

  • Fast high current loop test
  • Variable RCD current mode for customized settings
  • PASS/FAIL indication for RCD tests
  • Select voltage measurement between L-N, L-PE and N-PE
  • Zero adapter for easy test lead compensation, available as new accessory and also included with standard scope of supply
  • Extended Memory
  • Tech. Datasheet2.8 MB

Fluke 1654B - Multifunction Installation Tester (VDE 0100/0413)

  • Fast high current loop test
  • Variable RCD current mode for customized settings
  • PASS/FAIL indication for RCD tests
  • Select voltage measurement between L-N, L-PE and N-PE
  • Zero adapter for easy test lead compensation, available as new accessory and also included with standard scope of supply
  • Loop & Line Resistance - mΩ resolution (High Current)
  • Test smooth dc sensitive RCDs (Type B)
  • Extended Memory
  • Tech. Datasheet2.8 MB

Multifunktions-Installationstester Fluke 1662

  • delivers solid, basic installation testing features
  • Range(autoranging)20Ω/200 Ω/2.000 Ω
  • Accuracy of tTest voltage (at rated test current) + 10 %, -0 %
  • Sealing IP40
  • Bereich 500 V
  • Overload protection 660 V rms
  • Input impedance 360 kΩ
  • Tech. Datasheet475.8 kB

Multifunktions-Installationstester Fluke 1663

  • is the ideal choice for hard working professionals
  • Range(autoranging)20Ω/200 Ω/2.000 Ω
  • Accuracy of tTest voltage (at rated test current) + 10 %, -0 %
  • Sealing IP40
  • Bereich 500 V
  • Overload protection 660 V rms
  • Input impedance 360 kΩ
  • Tech. Datasheet475.8 kB

Multifunktions-Installationstester Fluke 1664

  • Multifunction Installation Tester helps expedite installations
  • Range(autoranging)20Ω/200 Ω/2.000 Ω
  • Accuracy of tTest voltage (at rated test current) + 10 %, -0 %
  • Sealing IP40
  • Bereich 500 V
  • Overload protection 660 V rms
  • Input impedance 360 kΩ
  • Tech. Datasheet475.8 kB

GSC 53N - Integrated instrument for tests on electrical installation and analysis on single and three phase electrical plants

  • Continuity test on protective conductors with 200mA
  • Insulation resistance
  • Tripping time and current of RCDs (type A, AC, general and selective)
  • Line/Loop impedance test in TN systems
  • Line/Loop impedance with high resolution (with IMP57 optional accessory)
  • Calculation of the prospective short circuit current
  • Loop resistance without tripping out of RCDs
  • Earth resistance and ground resistivity
  • Phase rotation
  • Power quality tests
  • Measurement and recording of TRMS value of electrical parameters
  • Harmonic analysis of voltage and current up to the 49th harmonic
  • Recording of the voltage anomalies (sags, swells) with 10ms resolution
  • Measurement and recording to leakage current
  • Measurement and recording of Temperature, Humidity, Illuminations
  • RS-232 interface
  • Tech. Datasheet471.6 kB

GSC 57 - Integrated instrument for complete verifies on electrical installation and power quality analysis on single and three phase systems

  • Continuity on protective conductors with 200mA
  • Continuity on protective conductors with 10A
  • Insulation resistance
  • Tripping time and current of RCDs (type A, AC, general and selective)
  • Line and Loop impedance and prospective short circuit current
  • Loop impedance with high resolution (with IMP57 optional accessory)
  • Global Earth Resistance without RCDs tripping
  • Earth resistance with 3-wire and 2-wire methods
  • Ground resistivity with 4-wire method
  • Contact voltage
  • Phase rotation
  • TRMS measure and recording (Voltages, Currents, Powers, etc)
  • Harmonic analysis of voltage and current up to the 49th order
  • Voltage anomalies (sags, spikes, breaks) with a 10ms resolution
  • Measurement and recording to leakage current to earth
  • Measurement and recording of Temperature (°C/°F), Humidity (HR%)
  • Measurement and recording Illuminations (Lux)
  • Save results inside memory
  • Recall measured test at display
  • Interface for PC communication
  • Auto Power OFF
  • Backlight
  • Tech. Datasheet497.9 kB

COMBI 419 - Multifunction meter for safety test verifies, automatic tests and use of remote probe

  • Continuity test with 200mA
  • Insulation with 50, 100, 250, 500, 1000VDC
  • Trip out time of RCDs type AC, A Standard and Selective
  • Trip out current of RCDs type AC, A Standard and Selective
  • Line/Loop Impedance P-P, P-N, P-PE
  • Line/Loop Impedance with high accuracy (with IMP57 optional accessory)
  • Prospective short circuit current
  • Contact voltage
  • Global Earth Resistance without RCD tripping
  • Phase sequence indication
  • AUTO function: (Ra + RDC test + Insulation) on plug
  • Measure with remote probe (with PR400 optional accessory)
  • Leakage current
  • Contextual help at display
  • Internal memory
  • Optical-USB interface with PC connection
  • Tech. Datasheet147.3 kB

COMBI 420 - Multifunction meter for safety test verifies, power measurements, automatic tests and use of remote probe

  • Continuity test with 200mA
  • Insulation with 50, 100, 250, 500, 1000VDC
  • Trip out time of RCDs type AC, A Standard and Selective
  • Trip out current of RCDs type AC, A Standard and Selective
  • Loop Impedance P-P, P-N, P-PE
  • Loop Impedance with high accuracy (with IMP57 optional accessory)
  • Prospective short circuit current
  • Contact voltage
  • Global Earth Resistance without RCD tripping
  • Phase sequence indication
  • AUTO function (Ra + RCDtest + Insulation) on plug
  • AC TRMS voltage and current
  • Active, Reactive, Apparent power and power factor on single phase system
  • Harmonics voltage/current up the 49th and THD% on single phase system
  • Environmental parameters measure (°C, °F, %RH, Lux, sound level)
  • Measure with remote probe (PR400 optional accessory)
  • Leakage current
  • Data HOLD
  • Contextual help at display
  • Internal memory
  • Optical-USB interface with PC connection
  • Tech. Datasheet147.3 kB

M 70 - Hand held meter for Insulation and Continuity of earth conductors measurements

  • Insulation with test voltage 250, 500, 1000VDC
  • Up to 4Gohm measurement range
  • utomatic discharge of device under test
  • LOCK feature for continuous measurements
  • Programmable timer up to 60s
  • Continuity of earth conductors with test current of 200mA
  • Automatic test leads calibration
  • A/DC voltage up to 600V
  • Resistance and continuity test with buzzer
  • Bargraph and backlight
  • AutoPowerOFF
  • Low battery indication
  • Protection rubber holster
  • Tech. Datasheet246 kB

M 72 - Portable meter for insulation/continuity tests and TRMS integrated multimeter

  • Insulation Resistance measurement with 250, 500VDC
  • Measurement range up to 1Gohm
  • Automatic discharging object after test
  • Continuity test of protective conductors with 200mA
  • Auto calibration of test leads
  • DC Voltage
  • AC TRMS Voltage
  • Automatic detection of AC/DC signals
  • AC TRMS Current with optional external clamp
  • AC TRMS Leakage current with optional external clamp
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with optional external clamp
  • Phase sequence indication at 1 or 2 wires method
  • Phase coincidence indication at 1 or 2 wires method
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function
  • Auto Power OFF
  • Tech. Datasheet267.3 kB

M 73 - Portable meter for global earth resistance, RCD tests and TRMS multimeter

  • Trip out time measure on AC Standard RCD
  • Trip out current selectable on 30, 30x5, 100, 300mA
  • Global Earth Resistance with 0.1mOhm resolution
  • Global Earth Resistance without RCD’s tripping
  • DC Voltage
  • AC TRMS Voltage
  • Automatic detection of AC/DC signals
  • AC TRMS Current with optional external clamp
  • AC TRMS Leakage current with optional external clamp
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with optional external clamp
  • Phase sequence indication at 1 or 2 wires method
  • Phase coincidence indication at 1 or 2 wires method
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function
  • Auto Power OFF
  • Tech. Datasheet266.7 kB

M 74 - Instrument for safety test on electrical plants and TRMS integrated multimeter

  • Continuity test of protective conductors with 200mA
  • Insulation Resistance measurement with 250, 500VDC
  • Trip-out time of RCDs type AC Standard
  • Selectable test current; 30mA, 30x5mA, 100mA, 300mA
  • Global Earth Resistance without RCD tripping
  • Global Earth Resistance with 0.1 resolution
  • Automatic test of global earth resistance + RDC test + insulation test
  • DC Voltage
  • AC TRMS Voltage
  • Automatic detection of AC/DC signals
  • AC TRMS Current with optional external clamp
  • AC TRMS Leakage current with optional external clamp
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with optional external clamp
  • Phase sequence indication at 1 or 2 wires method
  • Phase coincidence indication at 1 or 2 wires method
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function
  • Auto Power OFF
  • Tech. Datasheet272 kB

M 75 - Multifunction TRMS DMM, Safety test on electrical plants and Wire mapping Test on LAN cables

  • DC Voltage
  • AC TRMS Voltage
  • AC TRMS Current with External Clamp
  • AC TRMS Leakage current with external clamp (optional)
  • Resistance
  • Continuity test with buzzer
  • Frequency with test leads
  • Frequency with external clamp
  • MIN/MAX/AVG functions
  • PEAK function with response time 1ms
  • HOLD function
  • Continuity test of protective conductors with 200mA
  • Insulation Resistance measurement with 500VDC
  • Trip-out time of RCDs type AC Standard
  • Global Earth Resistance without RCD tripping
  • Global Earth Resistance with 0.1Ohm resolution
  • Phase sequence indication at 1 or 2 wires
  • Phase coincidence indication at 1 or 2 wire
  • Automatic test of global earth resistance + RDC test + Insulation test
  • Wire mapping test on LAN cables with RJ45 connector
  • Auto Power OFF
  • Tech. Datasheet267.9 kB

CA 6121 - complete testing tool for machine directive EN 60204

  • dielectric test: at 1,000, 1,250 and 1,500V AC with:
    • adjustment of max. current threshold
    • display of actual voltage and current
    • test with or without timer function
    • floating voltage-free outputs for greater safety
  • insulation test: 0 to 500MΩ at 500 or 1,000V DC with:
    • programming of the min resistance threshold
    • testing with or without timer function
  • continuity test: 0 to 2Ω at 12V / >10A AC with:
    • 4-wire measurement
    • voltage drop display (∆U: 0 to 10V
    • programming of the max. voltage drop and resistance threshold
    • testing with or without timer function
  • discharge time test: 0 to 10s at 600V AC/DC - measurement at 2 points (power supply terminals) or 4 points (internal components)
  • backlit LCD matrix screen
  • 1,000-measurement memory
  • RS232 output
  • remote control signals
  • software
  • software / remote control pedal / indicator lamps and printer available as options
  • IP54 site-proof casing
  • measurements in compliance with EN 60204-1, VDE 104 and EN 61180-1 and -2
  • electrical safety: IEC 1010 Cat. III 600V
  • dimensions: 250 x 260 x 400mm; weight: 11kg
  • Tech. Datasheet261.3 kB

CA 6160 - Appliance multitester

  • dielectric test: standard measurement modes (Un from 100 to 5,000V with Ilim 500mA) and programmed modes (t1, t2, t3, U1, U2)
  • continuity: up to 100Ω with 0.1 < ITEST < 25A
  • voltage drop: up to 100V (Itest > 10A)
  • insulation resistance: up to 1GΩ at 250/500VDC and 1,000VDC
  • measurement of internal and external discharge time (at the plug)
  • leakage current: operating and residual up to 20mA, contact up to 2mA
  • functional testing: voltage, current, frequency and power
  • AUTOTEST function for automatic execution of measurement sequence (up to 50)
  • large memory: 1,600 measurements
  • software to upload the stored data, generate test reports and program measurement sequences
  • delivered with all necessary measurement cables as standard and many optional accessories
  • dimensions: 410 x 175 x 370 mm - weight: 13.5kg
  • Tech. Datasheet774.6 kB

FULLTEST3 - IEC/EN61439-1 (switchgear and control gear) and IEC/EN60204-1 (electrical equipment for machinery) safety tester

  • Continuity of protection conductors with 200mA
  • Continuity of protection conductors with I>10A, V<12V AC
  • Continuity of protection conductors with I>25A, V<12V AC
  • Insulation resistance with 100,250,500,1000V DC
  • Withstanding with programmable test voltage from 250V to 5100V AC
  • Discharging time of internal capacitances and at the power input
  • Leakage/absorbed current and power consumption at the built-in test socket
  • Leakage current by means of the external transducer HT96U (optional)
  • Type A, AC, and B general, selective, and delayed RCDs up to 1000mA
  • Line/fault impedance with prospective short circuit current calculation
  • High resolution line/fault impedance (with IMP57 optional accessory)
  • Curve B, C, D, and K MCBs and type gG and aM fuses
  • Test I2t for verifies of short circuit conditions
  • Selection of length, type, and insulation of the cable under test
  • Selection of tripping time of the protection device under test
  • Non-trip earth loop impedance
  • Phase sequence indication
  • TFT display with touch-screen
  • Programmable timer
  • Programmable thresholds
  • Internal memory
  • USB interface for PC connection
  • USB interface for keyboard, printer and barcode reader connection
  • Tech. Datasheet2.3 MB
ICS SCHNEIDER MESSTECHNIK GmbH
Briesestraße 59,      D-16562 Hohen Neuendorf / OT Bergfelde
  • Tel.:     +49 3303 5040-66
  • Fax:     +49 3303 5040-68
  • E-Mail:     
Home
Sitemap
References
Contact
Impressum
AGB