testo 606-1 - moisture meter incl. protection cap, batteries and calibration protocol
- Accurate wood moisture measurement with stored characteristic curves for beech, spruce, larch, oak, pine, maple
- Additional characteristic curves to locate wet points in building materials for cement screed, concrete, plaster, anhydrite screed, cement mortar, lime mortar, brick
- Hold function for easy readout of readings
- Display illumination
- Self-test function
- Protective cap for safe storage
- Belt case, wrist strap and calibration protocol included
- Storage temperature -40 to +70 °C
- Operating temperature -10 to +50 °C
- Battery type 2 AAA micro batteries
- Battery life 200 h
- Weight 90 g
- Dimensions 119 x 46 x 25 mm
- Probe type Conductive measurement cell
- Meas. Range 0 to 50 %
- Accuracy ±1 %
- Resolution 0.1
testo 606-2 - wood and material humidity meter with integrated humidity measurement and NTC air thermometer incl. protection cap, batteries and calibration protocol
- Precise measurement of wood moisture with stored characteristics curves for beech, spruce, larch, oak, pine, maple
- Additional characterisitic curves for cement screed, concrete, plaster, anhydrite screed, cement mortar, lime mortar, brick
- Hold function for easy readout of readings
- Display illumination
- Self-test function
- Protective cap for safe storage
- Including wrist strap and belt holder
- Measurement of temperature and humidity in ambient air
- Air humidity measurement with the long-term stable Testo humidity sensor
- Incl. dewpoint calculation and wet bulb
- Storage temperature -40 to +70 °C
- Operating temperature -10 to +50 °C
- Battery type 2 AAA micro batteries
- Battery life 130 h
- Weight 90 g
- Dimensions 119 x 46 x 25 mm
- Probe type NTC
- Meas. range -10 to +50 °C
- Accuracy ±0.5 °C
- Resolution 0.1 °C
- Probe type Conductive measurement cell
- Meas. Range 0 to 50%
- Accuracy ±1%
- Resolution 0.1
- Probe type humid. sensor, cap.
- Meas. Range 0 to 100 %RH
- Accuracy ±2.5 %RH (5 to 95 %RH)
- Resolution 0.1 %RH
testo 610 - handy humidity/temperature meter incl. protection cap, batteries and calibration protocol
- Long-term stable Testo humidity sensor
- +/-2.5 %RH accuracy
- Incl. calibration protocol
- Dewpoint calculation and wet bulb included
- Hold function and max./min. values
- Protective cap for safe storage
- Belt case, wrist strap and calibration protocol included
- Backlit display
- Air moisture and air temperature
- Storage temperature -40 to +70 °C
- Operating temperature -10 to +50 °C
- Battery type 2 AAA micro batteries
- Battery life 200 h
- Weight 90 g
- Dimensions 119 x 46 x 25 mm
- Probe type NTC
- Meas. range -10 to +50 °C
- Accuracy ±0.5 °C
- Resolution 0.1 °C
- Probe type humid. sensor, cap.
- Meas. Range 0 to 100 %RH
- Accuracy ±2.5 %RH (5 to 95 %RH)
- Resolution 0.1 %RH
testo 616 - moisture meter for non-destructive measurement incl. battery
- Equipped with 10 characteristics curves for soft wood, hard wood, chipboard, anhydrite screed, cement screed, lime sand brick, aerated concrete, concrete, vertical hole brick and solid brick
- Measurement depth up to 5 cm
- Handy shape for optimum contact pressure
- Hold, max., min. function
- Illuminated digital display
- Characteristics curves were developed in cooperation with the LPI institut
- Advantageous for measurements on exotic woods: non-destructive determination of wood moisture
- Storage temperature -20 to +70 °C
- Operating temperature +5 to +40 °C
- Battery type 9V block battery, 6F22
- Battery life 60 h
- Weight 260 g
- Dimensions 70 x 58 x 234 mm
- Material/Housing ABS/TPE/Metal
- Probe type humid. sensor, cap.
- Resolution 0.1
testo 625 - humidity/temperature measuring instrument incl. plug-in humidity probe head, battery and calibration protocol
- Displays temperature and relative humidity / wet bulb temperature / dewpoint
- Max./min. values
- Hold button to freeze readings
- Display light
- Auto Off function
- TopSafe, the indestructible protection case (optional)
- Patented humidity sensor
- 2 year guaranteed long-term stability
- TopSafe, instrument protection against dirt and knocks (optional)
- Storage temperature -40 to +85 °C
- Operating temperature -20 to +50 °C
- Battery type 9V block battery, 6F22
- Battery life 70 h (without radio operation)
- Weight 195 g
- Dimensions 182 x 64 x 40 mm
- Material/Housing ABS
- Probe type NTC
- Meas. range -10 to +60 °C
- Accuracy ±0.5 °C
- Resolution 0.1 °C
- Probe type Type K
- Meas. Range -200 to +1370 °C
- Resolution 0.1 °C
- Probe type humid. sensor, cap.
- Meas. Range 0 to +100 %RH
- Accuracy ±2.5 %RH (+5 to +95 %RH)
- Resolution 0.1 %RH
testo 635-1 - thermohygrometer incl. battery and calibration protocol
- Testo printer for documenting measurement data on site
- Cyclical printing of readings once a minute, for example
- Measures air moisture, material equilibrium moisture, pressure dewpoint
- Radio probes for temperature and humidity
- Protection class IP54
- Storage temperature -30 to +70 °C
- Operating temperature -20 to +50 °C
- Battery type Alkali manganese, mignon, Type AA
- Battery life 200 h
- Weight 428 g
- Dimensions 220 x 74 x 46 mm
- Material/Housing ABS/TPE/Metal
- Probe type Typ T (Cu-CuNi)
- Meas. range -200 to +400 °C
- Accuracy
- ±0.3 °C (-60 to +60 °C)
- ±(0.2 °C + 0.3% of mv) (remaining range)
- Resolution 0.1 °C
- Probe type NTC
- Meas. range -40 to +150 °C
- Accuracy
- ±0.2 °C (-25 to +74.9 °C)
- ±0.4 °C (-40 to -25.1 °C)
- ±0.4 °C (+75 to +99.9 °C)
- ±0.5% of mv (remaining range)
- Resolution 0.1 °C
- Probe type Type K
- Meas. Range -200 to +1370 °C
- Accuracy
- ±0.3 °C (-60 to +60 °C)
- ±(0.2 °C + 0.3% of mv) (remaining range)
- Resolution 0.1 °C
- Probe type Absolute pressure probe
- Meas. Range 0 to 2000 hPa
- Resolution 0.1 hPa
- Probe type humid. sensor, cap.
- Meas. Range 0 to +100 %RH
- Resolution 0.1 %RH
testo 635-2 - humidity/temperature measuring instrument with measurement value store
- Instrument memory for up to 10,000 readings
- PC software for analysis, filing and documentation of measurement data
- Measurement of air moisture, material equilibrium moisture, pressure dew point
- Radio probe for temperature and humidity
- Protection class IP54
- Direct display of material moisture due to freely settable characteristics curves (based on equilibrium humidity)
- Storage of single measurements or measurement series by measurement location
- Fast access to the most important functions via user profiles
- U-value probe connection option
- Storage temperature -30 to +70 °C
- Operating temperature -20 to +50 °C
- Battery type Alkali manganese, mignon, Type AA
- Battery life 200 h (without radio operation)
- Weight 450 g
- Dimensions 220 x 74 x 46 mm
- Material/Housing ABS/TPE/Metal
- Probe type Typ T (Cu-CuNi)
- Meas. range -200 to +400 °C
- Accuracy
- ±0.3 °C (-60 to +60 °C)
- ±(0.2 °C + 0.3% of mv) (remaining range)
- Resolution 0.1 °C
- Probe type NTC
- Meas. range -40 to +150 °C
- Accuracy
- ±0.2 °C (-25 to +74.9 °C)
- ±0.4 °C (-40 to -25.1 °C)
- ±0.4 °C (+75 to +99.9 °C)
- ±0.5% of mv (remaining range)
- Resolution 0.1 °C
- Probe type Type K
- Meas. Range -200 to +1370 °C
- Accuracy
- ±0.3 °C (-60 to +60 °C)
- ±(0.2 °C + 0.3% of mv) (remaining range)
- Resolution 0.1 °C
- Probe type Absolute pressure probe
- Meas. Range 0 to 2000 hPa
- Resolution 0.1 hPa
- Probe type humid. sensor, cap.
- Meas. Range 0 to +100 %RH
- Resolution 0.1 %RH
testo 645 - Hochpräzise Messung für den Industriebereich
- Highly accurate humidity meas. to ±1%RH
- Internal data memory
- Convenient data analysis
- TopSafe for tough applications
- Channel 1: Temperature probe Type K/J/S, NTC
- Channel 2: Combi-probe humidity/temperature or temperature probe Pt100
- Storage temperature -20 to +70 °C
- Operating temperature 0 to +50 °C
- Battery type 9V block battery
- Battery life 45 h
- Weight 255 g
- Dimensions 215 x 68 x 47 mm
- Material/Housing ABS
- Probe type NTC
- Meas. range -50 to +150 °C
- Resolution 0.1 °C (-50 to +150 °C)
- Probe type Pt100
- Meas. range -200 to +800 °C
- Resolution 0.1 °C (-200 to +800 °C)
- Probe type Type K
- Meas. Range -200 to +1370 °C
- Resolution 0.1 °C (-200 to +1370 °C)
- Probe type humid. sensor, cap.
- Meas. Range 0 to +100 %RH
- Resolution 0.1 %RH (0 to +100 %RH)
- Probe type Typ J (FeCuNi)
- Meas. Range -40 to +750 °C
- Probe type Typ S (Pt10Rh Pt)
- Meas. Range -50 to +1700 °C
CA 846 - Thermo-Hygrometer
- 3½-digit display (2,000 counts)
- functions: MAX / HOLD / °C or °F / Backlighting
- measurement range: -20°C to +60°C; -0 to 100%RH
- temperature accuracy: ±0.5°C from 0 to 60°C, ± 1°C from -20°C to 0°C
- Hygrometric accuracy: ±2.5% at 25 °C from 10 to 90 % RH, ±10% at 25 °C from 0 to 10 % RH and from 90 to 100 % RH
- resolution: 0.1°C and 0.1%RH
- shockproof protective sheath
- dimensions: 173 x 60.5 x 38mm - Weight: 185g
CA 847 - Materials Moisture Meter
- 2 display scales using 20 LEDs: 6 to 23% / 24 to 100%
- integrated, replaceable electrodes (L=12 mm)
- utilisation environment: 0 to 50°C (<80% RH)
- battery charge indicator
- dimensions: 195 x 60.5 x 38 mm - weight: 160g
- shockproof protection cover
testo 845 - infrared temperature measuring instrument with cross laser sighting incl. humidity module, switchable optics for far-field and close focus measurement
- Switchable optics for far-field measurements (75:1) and close focus (1 mm, distance 70 mm)
- Especially bright cross laser sighting for indicating the actual measurement point
- Integrated humidity module for measuring indoor air humidity and for determining dewpoint distance
- Reference accuracy ± 0.75 °C with super-fast measurement technology (scanning 100 ms)
- Backlit display (3-line), shows °C, %RH, °C td, min./max. values, alarm limit values and degree of emission
- Optical and audible alarm when limit values are exceeded
- Probe socket for TC probe for determining emissivity
- Instrument memory for 90 measurement protocols
- PC software for archiving and documenting measurement data (included in delivery)
- Tripod fitting for online measurement via USB cable (included in delivery)
- Measurement data documentation on site with Testo printer
- Storage temperature -40 to +70 °C
- Operating temperature -20 to +50 °C
- Battery type 2 AA batteries
- Weight 465 g
- Dimensions 155 x 58 x 195 mm
- Material/Housing ABS
- Probe type Type K
- Meas. Range -35 to +950 °C
- Accuracy
- ±0.75 °C (-35 to +75 °C)
- ±1% of mv (+75.1 to +950 °C)
- Resolution 0.1 °C
- Probe type Infrared
- Meas. Range -35 to +950 °C
- Accuracy
- ±2.5 °C (-35 to -20.1 °C)
- ±1.5 °C (-20 to +19.9 °C)
- ±0.75 °C (+20 to +99.9 °C)
- ±0.75% of mv (+100 to +950 °C)
- Resolution 0.1 °C
- Probe type humid. sensor, cap.
- Meas. Range 0 to +100 %RH / 0 to +50 °C / -20 to +50 °C td
- Accuracy
- ±2 %RH (2 to 98 %RH)
- ±0.5 °C (+10 to +40 °C) ±1 °C (remaining range)
- Resolution 0.1 °C td / 0.1 %RH