ICS-Schneider Messtechnik GmbH
  • Deutsch
  • English
  • Products
  • Company
    • About Us
    • Jobs & Carrers
    • Calibration
  • News
    • News
    • Sale actions
  • Downloads
  • Contact

Products

  • Manometer / Gauges / Accessories
  • Thermometer / Temperature sensors
  • Pressure and Temperature switches
  • Pressure sensors / Transmitter / diff. Pressure sensors / Level sensors
  • Flowsensors / Waysensors / Powersensors / Waagen
  • Humiditysensors / Velocitysensors
    • Humidity sensors / Humidity equipment
    • Velocity equipment / Velocity sensors
      • Flowmeters
      • Mobile flowmeters
    • pH / Conductivity / Oxygen
  • Calibrators, Test kits
  • Calibration pumps
  • Pressure controller
  • Pressure meters
  • Temperature meters / Thermography
  • Gas meters and Gas sensors
  • Dataloggers and Measuring systems
  • Minimess
  • Analog meters/ Digital meters / Current Voltage transformers / Transducers / Buffer
  • Network equipment
  • Dynisco products
  • Energy meters / VDE check equimpemnt
  • Home
  • Products
  • Humiditysensors / Velocitysensors
  • Flowmeters

Flowmeters

IVA 500 - for flow measurement of compressed air and gases

  • RS 485 interface, Modbus-RTU as a standard
  • Integrated display for m³/h and m³
  • Usable from 1/2“ to 12“ (DN 300)
  • Easy installation under pressure
  • 4...20 mA analogue output for m³/h resp. m³/min
  • Pulse output for m³
  • Inner diameter adjustable via keypad
  • Consumption counter resettable
  • Adjustable via keys at the display: Gas type, reference conditions, °C and mbar, 4...20 mA scaling, pulse weight
  • Tech. Datasheet3.3 MB

IVA 520 - the affordable flow meter for compressed air and gases

  • The integrated Modbus interface enables the connection to superordinated control systems like energy management systems, building management systems, SPS, SCADA,
  • Easy and affordable installation
  • Units freely selectable via keys at the display m³/h, m³/min, l/min, l/s, kg/h, kg/min, kg/s, cfm
  • Compressed air counter up to 1.999.999.999 m³. Resetable to „zero“ via keypad
  • Analogue output 4...20 mA, pulse output (galvanically separated)
  • High measuring accuracy also in the lower measuring range (ideal for leakage measurement)
  • Negligibly small loss of pressure
  • Calorimetric measuring principle, no additional pressure and temperature measurement necessary, no mechanically moved parts
  • Comprehensive diagnosis functions can be read out at the display or by remote access via Modbus-RTU like e. g. exceeding Max./Min values °C, calibration cycle, error codes, serial number. All parameters can be read out and changed via Modbus
  • Tech. Datasheet3.3 MB

IVA 550 - Präzise Verbrauchs- / Durchflussmessung für Druckluft und Gase

  • ideal auch für den Außenbereich
  • Druckluftmessung und Verteilung
  • leckagemessung von Druckluft und Gasen
  • Verbrauchsmessung von Gasen wie z.B. Stickstoff, Argon, Kohlendioxid, Sauerstoff etc.
  • Verbrauchsmessung in Vakuumanlagen
  • Verbrauchsmessung von explosiven Gasen wie Erdgas, Methan, Propan, Wasserstoff mit ATEX Zulassung
  • Verbrauchsmessung von korrosiven, ätzenden Gasen wie z.B. Biogas mit unterschiedlichen Gasgemischen
  • Messung von Sauerstoff und Erdgas an Gasbrennern
  • Verbrauchsmessung von Gasgemischen wie z.B. Formiergas
  • Tech. Datasheet

IVA 570 - Präzise Verbrauchs- / Durchflussmessung für Druckluft und Gase mit integrierter Messstrecke

  • ideal auch für den Außenbereich
  • Druckluftmessung und Verteilung
  • leckagemessung von Druckluft und Gasen
  • Verbrauchsmessung von Gasen wie z.B. Stickstoff, Argon, Kohlendioxid, Sauerstoff etc.
  • Verbrauchsmessung in Vakuumanlagen
  • Verbrauchsmessung von explosiven Gasen wie Erdgas, Methan, Propan, Wasserstoff mit ATEX Zulassung
  • Verbrauchsmessung von korrosiven, ätzenden Gasen wie z.B. Biogas mit unterschiedlichen Gasgemischen
  • Messung von Sauerstoff und Erdgas an Gasbrennern
  • Verbrauchsmessung von Gasgemischen wie z.B. Formiergas

testo 6441 - compressed air meter

  • Parameters: standard volumetric flow rate in Nm³/h or Nl/min; consumption quantity in Nm³; media temperature in °C
  • Output signals: The following 2 outputs are enabled for selection at the same time:
    • Analog output, 4 to 20 mA (4-wire)
    • Pulse output
    • 2 switch signals, programmable (dependent on consumption or volumetric flow rate, time-based or non time-based, NC or NO contact, hysteresis, window)
  • Extremely easy to operate using just 2 control buttons
  • Design with inflow stretch
    • Advantage: reliable accuracy, including in installed state!<
    • Reason: The sensor is calibrated to the pipe section (Nm³/h not m/s) -> optimum flow profile, hence no loss of accuracy through specification of incorrect pipe diameter, incorrect positioning (depth/torsion)!
  • Tech. Datasheet663.8 kB

testo 6442 - compressed air meter

  • Parameters: standard volumetric flow rate in Nm³/h or Nl/min; consumption quantity in Nm³; media temperature in °C
  • Output signals: The following 2 outputs are enabled for selection at the same time:
    • Analog output, 4 to 20 mA (4-wire)
    • Pulse output
    • 2 switch signals, programmable (dependent on consumption or volumetric flow rate, time-based or non time-based, NC or NO contact, hysteresis, window)
  • Extremely easy to operate using just 2 control buttons
  • Design with inflow stretch
    • Advantage: reliable accuracy, including in installed state!<
    • Reason: The sensor is calibrated to the pipe section (Nm³/h not m/s) -> optimum flow profile, hence no loss of accuracy through specification of incorrect pipe diameter, incorrect positioning (depth/torsion)!
  • Tech. Datasheet663.8 kB

testo 6443 - compressed air meter

  • Parameters: standard volumetric flow rate in Nm³/h or Nl/min; consumption quantity in Nm³; media temperature in °C
  • Output signals: The following 2 outputs are enabled for selection at the same time:
    • Analog output, 4 to 20 mA (4-wire)
    • Pulse output
    • 2 switch signals, programmable (dependent on consumption or volumetric flow rate, time-based or non time-based, NC or NO contact, hysteresis, window)
  • Extremely easy to operate using just 2 control buttons
  • Design with inflow stretch
    • Advantage: reliable accuracy, including in installed state!<
    • Reason: The sensor is calibrated to the pipe section (Nm³/h not m/s) -> optimum flow profile, hence no loss of accuracy through specification of incorrect pipe diameter, incorrect positioning (depth/torsion)!
  • Tech. Datasheet663.8 kB

testo 6444 - compressed air meter

  • Parameters: standard volumetric flow rate in Nm³/h or Nl/min; consumption quantity in Nm³; media temperature in °C
  • Output signals: The following 2 outputs are enabled for selection at the same time:
    • Analog output, 4 to 20 mA (4-wire)
    • Pulse output
    • 2 switch signals, programmable (dependent on consumption or volumetric flow rate, time-based or non time-based, NC or NO contact, hysteresis, window)
  • Extremely easy to operate using just 2 control buttons
  • Design with inflow stretch
    • Advantage: reliable accuracy, including in installed state!<
    • Reason: The sensor is calibrated to the pipe section (Nm³/h not m/s) -> optimum flow profile, hence no loss of accuracy through specification of incorrect pipe diameter, incorrect positioning (depth/torsion)!
  • Tech. Datasheet663.8 kB

testo 6446 - compressed air meter - sensor can also be changed under pressure

  • Parameters: standard volumetric flow rate in Nm³/h or Nl/min; consumption quantity in Nm³
  • 14 diameter types between DN 65 (21/2“) and DN 250 (10“)
  • Output signals: The following 2 outputs are enabled for selection at the same time:
    • Analog output, 4 to 20 mA (4-wire)
    • Pulse output
    • 2 switch signals, programmable (dependent on consumption or volumetric flow rate, NC or NO contact, hysteresis, window)
  • Choice of pipe materials: Stainless steel or galvanized steel
  • All versions with display: volumetric flow rate or consumption
  • Patented screw fitting for quick and easy removal of sensor electronic unit under pressure, without interrupting operation, for cleaning and recalibration
  • Design with inflow stretch
    • Advantage: reliable accuracy, including in installed state!
    • Reason: The sensor is calibrated to the pipe section (Nm³/h not m/s) -> optimum flow profile, hence no loss of accuracy through specification of incorrect pipe diameter, incorrect positioning (depth/torsion)!
  • Tech. Datasheet651.7 kB

testo 6447 - compressed air meter - sensor can also be changed under pressure

  • Parameters: standard volumetric flow rate in Nm³/h or Nl/min; consumption quantity in Nm³
  • 14 diameter types between DN 65 (21/2“) and DN 250 (10“)
  • Output signals: The following 2 outputs are enabled for selection at the same time:
    • Analog output, 4 to 20 mA (4-wire)
    • Pulse output
    • 2 switch signals, programmable (dependent on consumption or volumetric flow rate, NC or NO contact, hysteresis, window)
  • Choice of pipe materials: Stainless steel or galvanized steel
  • All versions with display: volumetric flow rate or consumption
  • Patented screw fitting for quick and easy removal of sensor electronic unit under pressure, without interrupting operation, for cleaning and recalibration
  • Design with inflow stretch
    • Advantage: reliable accuracy, including in installed state!
    • Reason: The sensor is calibrated to the pipe section (Nm³/h not m/s) -> optimum flow profile, hence no loss of accuracy through specification of incorrect pipe diameter, incorrect positioning (depth/torsion)!
  • Tech. Datasheet651.7 kB

testo 6448 - Compressed air counter shaft probe DN40 - DN250

  • Possibility of installation under pressure
  • Measurement of flow velocity in the measuring range 0 to 80 m/s or 160 m/s; consumption measurement in m3 and media temperature in °C
  • Recoil protection and ball valve ensure fast and safe installation and deinstallation of the compressed air probe
  • Highest flexibility thanks to different signal outputs:
    • Analog output 4 to 20 mA (4-wire)
    • Pulse output
    • 2 switching outputs (consumption or volume flowdependent)
  • Integrated totalizer, also without additional evaluation unit
  • Operating menu with LED display
  • Tech. Datasheet652.1 kB