ICS-Schneider Messtechnik GmbH
  • Deutsch
  • English
  • Products
  • Company
    • About Us
    • Jobs & Carrers
    • Calibration
  • News
    • News
    • Sale actions
  • Downloads
  • Contact

Products

  • Manometer / Gauges / Accessories
  • Thermometer / Temperature sensors
  • Pressure and Temperature switches
  • Pressure sensors / Transmitter / diff. Pressure sensors / Level sensors
  • Flowsensors / Waysensors / Powersensors / Waagen
  • Humiditysensors / Velocitysensors
  • Calibrators, Test kits
  • Calibration pumps
  • Pressure controller
  • Pressure meters
  • Temperature meters / Thermography
  • Gas meters and Gas sensors
  • Dataloggers and Measuring systems
  • Minimess
  • Analog meters/ Digital meters / Current Voltage transformers / Transducers / Buffer
    • Analog meters
    • Digital meters
    • Current transformers with transducer
    • Current transformers / Voltage transformers
    • Shunt
    • Transducers
    • Isolation amplifier
    • Energy meters
    • Energymanagement
    • Limit signal generator / Limit value relais / Recorders
      • Analog limit signal generator
      • Differenz limit signal generator
      • Isolation limit signal generator
      • Recorder limit signal generator
    • Switch position indicators
  • Network equipment
  • Dynisco products
  • Energy meters / VDE check equimpemnt
  • Home
  • Products
  • Analog meters / Digital meters
  • Differenz signal generator

Differenz signal generator

Delta RD1A - Residual current device 2 Module

  • Istantaneous:(t = 0) at IDeltan 30mA
  • Selectable set point 30mA…30A (19 ranges)
  • Field-selectable negative or positive security (fail safe)
  • Automatic permanent test
  • Manual or automatic reset (3 restart attempts)

Delta RD3A - Residual curent device

  • Selectable set point 30mA ... 30A (19 ranges)
  • lstantaneous display as percentage of /Li n
  • 2-wire connections relay ring current transformet
  • Filter for harmonics
  • Field-se/ectable negative or positive security (fail safe)
  • Automatie permanent test
  • Manual or automatic reset (3 restart attempts)

Delta RD2B - Residual current device 4 Module

  • Use in unattented environments (public lighting, traffic lights plants)
  • Automatic reset (max.3 attempts)
  • in the event of transient ground fault
  • Instantaneous (t = 0) at I Δn 30mA
  • Selectable set point 30mA…30A (19 ranges)
  • Instantaneous display as percentage of I Δn
  • Filter for harmonics, field-selectable
  • Field-selectable negative or positive security (fail safe)
  • Automatic permanent test

Differenzstromrelais Delta RD3B2 (4 Modul)

Delta RD4B2 - Residual current device

  • Instantaneous (t = 0) at I Δn 30mA
  • Selectable set point 30mA…30A (19 ranges)
  • Instantaneous display as percentage of I Δn
  • Alarm + pre-alarm or alarm function with 2 SPDT contact
  • Field-selectable negative or positive security (fail safe)
  • Automatic permanent test
  • Automatic restart (up to 10 attempts) in case of transient earth fault
  • “No trip” TEST (local, without output relay tripping)
  • Sealable front frame

Delta 48-S RD1DF - Residual current device 48x 48mm

  • Instantaneous (t = 0) at I Δn 30mA
  • Selectable set point 30mA…30A (19 ranges)
  • Field-selectable negative or positive security (fail safe)
  • Automatic permanent test
  • Manual or automatic reset (3 restart attempts)

Delta 48-S (RD1D2) - Residual current device

  • Istantaneous (t = 0) at I Δ n 30mA
  • Selectable set point 30mA…30A (19 ranges)
  • Field-selectable negative or positive security (fail safe)
  • Automatic permanent test
  • Manual or automatic reset (3 restart attempts)

Delta 72-S (RD1EP) - Residual current device (72x72mm)

  • Instantaneous (t = 0) at I Δn 30mA
  • Selectable set point 30mA…30A (19 ranges)
  • Instantaneous display as percentage of I Δn
  • Pre-alarm threshold
  • Field-selectable negative or positive security (fail safe)
  • Automatic permanent test
  • Manual or automatic reset (3 restart attempts)
  • Tech. Datasheet126.5 kB

Delta 72-S (RD1EP) - Residual current device (72x72mm)

  • Instantaneous (t = 0) at I Δn 30mA
  • Selectable set point 30mA…30A (19 ranges)
  • Instantaneous display as percentage of I Δn
  • Pre-alarm threshold
  • Field-selectable negative or positive security (fail safe)
  • Automatic permanent test
  • Manual or automatic reset (3 restart attempts)
  • Tech. Datasheet714.7 kB

Differenzstromrelais Delta RD2E2 (Schalttafeleinbau 72x72mm)

Residual current device Delta 72-h (RD3E)(96x96mm)

RD1G - Residual current device 96x96mm

  • Instantaneous (t = 0) at I Δn 30mA
  • Selectable set point 30mA…30A (19 ranges)
  • Instantaneous display as percentage of I Δn
  • Field-selectable negative or positive security (fail safe)
  • Automatic permanent test
  • Alarm relay + pre-alarm or alarm relay with double exchange

Residual current device Delta 96-s (RD1G2)(96x96mm)

Selectable set point 30mA...30A (11 ranges)

Transformer DEL (TDGA 2)

Closed-core ring current-transformer for residual current devices

Transformer DEL(TDG..)

Closed-core ring current-transformer for residual current devices

Transformer DEL(TDG..)

Closed-core ring current-transformer for residual current devices

DEL (TDS) - Transformers

Summing ring current transformer for differential protection with measuring CT transformer

Transformer DEL A (TDA..)

Open-core ring current-transformers for residual current devices

Transformer DEL A (TDAC 2)

Open-core ring current-transformers for residual current devices
ICS SCHNEIDER MESSTECHNIK GmbH
Briesestraße 59,      D-16562 Hohen Neuendorf / OT Bergfelde
  • Tel.:     +49 3303 5040-66
  • Fax:     +49 3303 5040-68
  • E-Mail:     
Home
Sitemap
References
Contact
Impressum
AGB